Videx VX2200 Manual de usuario Pagina 16

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 28
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 15
LU
CPU
Telephones
4 way junction box
Landing Unit
SP400 control cabinet
with proximity controller
VX2200 digital or
functional door panel
with proximity reader
12Vdc fail secure or fail
open lock release
Product Key
VX2200 Block Diagram
1 or more Audio entrances with proximity access control to multiple
apartments using Art.3171 or Art.3172 telephones
VIDEX SECURITY LTD, UNIT 4-7 CHILLINGHAM IND. EST., NEWCASTLE
UPON TYNE, NE6 2XX
TEL 0870 300 1240 FAX 0191 224 5678 E-MAIL SALES@VIDEX-
SECURITY.COM WEB WWW.VIDEX-SECURITY.COM
CPU
LU
LU
LU
LU
LU
LU
2
8
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
8
CPU
6
8S
4S
8S
Min. cable requirements
Max. distance 100m
1 Pair
AWG22 (0.325mm²)
Resistance/km 54.12
Ω
6 Pair
AWG22 (0.325mm²)
Resistance/km 54.12Ω
Max. distance 200m
1 Pair
AWG20 (0.5mm²)
Resistance/km 32.8Ω
6 Pair
AWG20 (0.5mm²)
Resistance/km 32.8Ω
Max. distance 350m
1 Pair
AWG18 (0.8mm²)
Resistance/km 19.2Ω
6 Pair
AWG18 (0.8mm²)
Resistance/km 19.2Ω
Consult the VX2200 cable guide for
more information
4
2
2
4
2
4
Notes:
Two extra cores required to the telephone’s if
the local door bell facility is required (Not
available on isolation systems)
Proximity readers must be no more than 50
meters from their controller. A suitable
screened cable could be (20AWG, 4 Pair)
6
6
6
Vista de pagina 15