Busca en linea o descarga Guía para resolver problemas para Sistemas de intercomunicación de la puerta Videx 3000 SERIES. Videx 3000 SERIES Troubleshooting guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 2

8 Art.3121 Intercom made from white ABS shockproof plastic with “door-open” and “service” push buttons. It has electronic call tone with the volume

Pagina 3

9Art.3126 As the Art.3125 but with timed privacy, the duration depends on the JP2 settings: Position Duration A about 8 minutes B ¼ hour C ½ hour D

Pagina 4

10 POWER SUPPLIES ALIMENTATORI INSTALLATION Install the power supply as follows, also referring to the General Directions for Installation on pag

Pagina 5

11ENSLAVEMENT RELAY MODULES MODULI RELÈ DI ASSERVIMENTO ART.506N Enslavement Relay (230Vac 5A max) enables the control of stair lights or other

Pagina 6

12 ART.509N It incorporates a modulated tone generator plus a system reset circuit. It is necessary on “4+1” audio door entry systems with privacy o

Pagina 7 - INTRODUZIONE

13 - The relays in the switch have two positions (“A” and “B”). To enable the switching to one of the two positions it is necessary to draw a curren

Pagina 8 - CITOFONI

14 800 SERIES MODULAR SYSTEM SISTEMA MODULARE SERIE 800 Videx manufacture a range of modular push button panels that allow for an easy and cost effe

Pagina 9

15Terminals: 2 Speech output. 13Vac power input for the LEDs. 3 +8Vdc power input. 1 Speech input. 4 Speech ground. Ground (0V) for 13Vac. P2 Call

Pagina 10

16 EXTENSION MODULES MODULI PULSANTIERA Art.842, 843, 844, 845 These modules have only call buttons and the lamp for illuminating the name plates.

Pagina 11

17ACCESS CONTROL MODULES MODULI PER IL CONTROLLO ACCESSI Art.VX800N-2,VX800N-2L,VX800N-3,VX800N-3L,VX900N-2,VX900N-2L These modules have a toug

Pagina 13

18 Terminals: - Ground 12 12Vdc power supply RK Data Signal LR Red LED signal LG Green LED signal Access control systems operating by proximity key

Pagina 14 - SCAMBIATORI DI INGRESSI

19 Art. Modules Columns Dimensions (mm) Moduli Colonne Dimensioni (mm) 861A 1 1 135x166 1 1 135x166 862A 2 1 135x286 2 1 135x286 863A 3 1 135x406 3

Pagina 15

20 EXAMPLES OF MODULE COMBINATIONS (1 TO 42 BUTTONS) Below are examples of how to combine modules to get the required number of push buttons. The sp

Pagina 16 - SISTEMA MODULARE SERIE 800

21NOTES AND SUGGESTIONS FOR A CORRECT INSTALLATION NOTE E SUGGERIMENTI PER UNA CORRETTA INSTALLAZIONE On the previous page are shown some examples b

Pagina 17

22 2 MODULES OUTDOOR STATION MOUNTING PROCEDURE Flush mounting (Fig.5) a. Mount the box (1) at 165-170 cm. from ground level (as shown on fig.4);

Pagina 18

23INSTALLING ACCESSORIES AND ADDITIONAL COMPONENTS INSTALLAZIONE ACCESSORI E COMPONENTI ADDIZIONALI

Pagina 20

25GENERAL DIRECTIONS FOR INSTALLATION NORME GENERALI DI INSTALLAZIONE In order to achieve the best results from the schematics described it is neces

Pagina 21

26 TROUBLESHOOTING GUIDE Depending on fault found, carry out the following preliminary checks: - Measure the mains power between terminals 230V (or

Pagina 22

27The electric lock does not work: - Pressing the “door open” push button, check that the voltage on the electric lock terminals is higher than 10Va

Pagina 23 - INSTALLAZIONE

1INDEX INDEX ... 1 INTRODUCTION ...

Pagina 24

28 Feedback (Larsen effect): - Microphone of the speaker unit or of the handset out of housing; - Adjust volumes (may be to high); - Intercom defect

Pagina 25

29No speech between extensions: - Wires “A” or “B” broken or in short circuit; - Call made without lifting the handset; - Art.510N defective. No sp

Pagina 26

30 NOTES NOTE

Pagina 27 - TESTING INSTALLATION

31WIRING DIAGRAMS SCHEMI APPLICATIVI Here are some examples of installations for “3+1” without privacy of speech, “4+1” and “1+1” audio door entry s

Pagina 28

32 “3+1” AUDIO DOOR ENTRY SYSTEMS SISTEMI CITOFONICI “3+1” ONE ENTRANCE AUDIO DOOR ENTRY SYSTEM FOR “n” USERS This diagram shows a basic “3+1” syst

Pagina 30

34 TWO ENTRANCE AUDIO DOOR ENTRY SYSTEM FOR “N” USERS The system works like the one shown on page 32 but it has two entrances. The Art.502N (audio e

Pagina 32 - NOTES NOTE

36 THREE OR MORE ENTRANCE AUDIO DOOR ENTRY SYSTEM FOR “N” USERS The system works like the one shown on page 32 but is for three or more entrances. T

Pagina 34 - SISTEMI CITOFONICI “3+1”

2 INDICE INDICE ... 2 INTRODUZIONE...

Pagina 35

38 ONE ENTRANCE WITH PROXIMITY KEY READER AUDIO DOOR ENTRY SYSTEM FOR “20” USERS (FIG.1) The figure 1 diagram shows the standard system on page 32 w

Pagina 37

40 “4+1” AUDIO DOOR ENTRY SYSTEMS WITH PRIVACY OF SPEECH AND FULL LOCK SISTEMI CITOFONICI “4+1” CON SEGRETO DI CONVERSAZIONE E BLOCCO SERRATURA O

Pagina 39

42 TWO ENTRANCES AUDIO DOOR ENTRY SYSTEM FOR “N” USERS The system works like the one on page 40 but has two entrances. The Art.502N (audio entrances

Pagina 41

44 THREE OR MORE ENTRANCES AUDIO DOOR ENTRY SYSTEM FOR “N” USERS The system works like the one shown on page 40 but has three or more entrances. A c

Pagina 43

46 “1+1” AUDIO DOOR ENTRY SYSTEMS SISTEMI CITOFONICI “1+1” ONE ENTRANCE AUDIO DOOR ENTRY SYSTEM FOR “N” USERS The “1+1” system, based on a common w

Pagina 45

3TECHNICAL MANUAL DOOR PHONE SYSTEMS& WIRING DIAGRAMS MANUALE TECNICO CITOFONICO E SCHEMARIO

Pagina 46

48 TWO ENTRANCES AUDIO DOOR ENTRY SYSTEM FOR “N” USERS The system works like the one on page 46 but has two entrances. The Art.502N (audio entrances

Pagina 48 - SISTEMI CITOFONICI “1+1”

50 THREE OR MORE ENTRANCES AUDIO DOOR ENTRY SYSTEM FOR “N” USERS The system works like the one on page 46 but has three entrances. The call from one

Pagina 50

52 ONE ENTRANCE WITH PROXIMITY KEY READER AUDIO DOOR ENTRY SYSTEM FOR “20” USERS (FIG.1) The figure 1 diagram shows the basic system on page 46 addi

Pagina 52

54 INTERCOMMUNICATING DOOR ENTRY SYSTEMS SISTEMI CITOFONICI INTECOMUNICANTI TWO USER INTERCOMMUNICATING SYSTEM The diagram on figure “A” shows a t

Pagina 54

56 FIVE USERS INTERCOMMUNICATING SYSTEM WITHOUT OUTDOOR STATION The diagram shows an intercommunicating system which uses five push button intercoms

Pagina 57

58 FIVE USERS INTERCOMMUNICATING SYSTEM WITH ONE ENTRANCE The diagram shows the installation of page 56 complete with the outdoor station. Operatio

Pagina 59

60 FIVE USERS INTERCOMMUNICATING SYSTEM WITH TWO ENTRANCES The installation shown on the diagram works like the one on page 58 but has two entrances

Pagina 61

62 FIVE USERS INTERCOMMUNICATING SYSTEM WITH THREE ENTRANCES The installation shown on the diagram works like the one on page 58 but has three or mo

Pagina 63

64 See page 66 for system description. Vedi pagina 66 per la descrizione dell’impianto. ONE MAIN ENTRANCE PLUS THREE SECONDARY ENTRANCES AUDIO DOOR

Pagina 64

65See page 66 for system description. Vedi pagina 66 per la descrizione dell’impianto.

Pagina 65

66 “3+1” AUDIO DOOR ENTRY SYSTEMS SISTEMI CITOFONICI “3+1” ONE MAIN ENTRANCE PLUS THREE SECONDARY ENTRANCES AUDIO DOOR ENTRY SYSTEM The diagram sho

Pagina 66

67NOTES NOTE

Pagina 67

5INTRODUCTION INTRODUZIONE The VIDEX products described in this manual can be used to make audio door phone systems to satisfy all needs. The full r

Pagina 68

68 NOTES NOTE

Pagina 71

6 INTERCOMS CITOFONI FOR “3+1” & “4+1” SYSTEMS PER SISTEMI “3+1” E “4+1” Art.3101 Intercom made from white ABS shockproof plastic with “door-o

Pagina 72

7Terminals: 4 Electronic call tone input 6 Unused 2 Speech line input from outdoor station microphone to handset speaker Speech line output from han

Comentarios a estos manuales