VPROX 4000 ADVANCED OPTIONS
• Programming CPU clock time and date.
• Creating user download information.
• Editing deletion and addition of individual keys without full system upload.
• One shot key programming (once used key is invalid).
• Date stamped key (invalid after specified date).
• Assign key credits (allowing specified number of key operations).
• Full monitoring of 20 main doors (with the addition of door monitoring unit).
VPROX 4000/DM
The addition of the door monitoring module to the Vprox 4000 enhances even further the
flexibility and security of the system. An individual module will monitor 4 doors and connects to
the same 3 wire serial BUS as the Vprox 1000A. A system can accommodate 5 modules, allowing
the monitoring of 20 entrance doors. When connected, the PC will monitor the status of all the
connected doors including the duration of the door open time.